8

QS-WT-T36K Waterproof Test Box

2024/3/13


Splash and spray tests for large components

Applicable standards

ISO 20653,IPX3/X4/X4K/X5/X6/X6K

IEC 60629,IPX3/X4/X5/X6

GB/T 30038,IPX3/X4/X4K/X5/X6/X6K

GB/T 4208,IPX3/X4/X5/X6

IEC 60068-2-18,IPX3/X4/X5/X6

GB/T 2423.38,IPX3/X4/X5/X6

IEC 60598-1,IPX3/X4/X5/X6

GB 7000.1,IPX3/X4/X5/X6

IEC 60034-5,IPX3/X4/X5/X6

GB/T 4942.1,IPX3/X4/X5/X6

GB/T 10485,防水试验 方法B


Specificities

Reliable and stable systems

- The water tank is arranged with a low level switch and a high level switch to keep the water tank level at a high level through automatic replenishment, and the system alarm will be triggered when the level reaches a low level due to failure to replenish water in time.
- The water tank refill circuit is arranged with a filter to avoid debris entering the water tank and blocking the nozzle, and the filter needs to be replaced regularly.
- The pump suction port is arranged with a filter to avoid debris entering the pump and causing damage.
- Combined use of large and small flow pumps, according to the flow rate required for the test automatically turn on the corresponding pumps
- The flow rate is adjusted by a proportional three-way valve, and the proportional valve is adjusted by the flow rate value fed back from the flow meter, so as to achieve the accuracy and stability of the flow rate.


High-performance components

- Water pumps

Grundfos compact and highly reliable horizontal multistage end-suction centrifugal pumps with axial suction and radial discharge ports for providing sufficient water flow in water circuit systems; the pump body in contact with the liquid is made of stainless steel and the pump is fitted with a 3-phase asynchronous motor with a cooling fan; the pumps are small, quiet and reliable




- Three-way proportional valves

Danfoss electric intelligent control valve, used to control the water flow to meet the test standard requirements; control valve by the regulator valve and pressure relief control valve, control signal automatic disconnection monitoring, free self-test positioning, anti-oscillation, overheating and overload protection and other functions, to ensure that the control of the stable and accurate

- Flow Sensors

Vortex flow sensor, used to measure the flow in the water circuit, providing analog signals to the control system for flow control; quick-insertion installation, easy to disassemble and calibrate; contaminants in the fluid have no effect on the measuring element, small pressure loss, and extremely high accuracy.


- Pressure Sensor

Measuring range 0~16bar, used to measure the pressure in the water circuit, provide analog signal to the control system for pressure monitoring; 304 stainless steel manufacturing, better than 0.3% of the full-scale accuracy, threaded connection, easy to disassemble calibration


- Servo motor

Siemens SINAMICS V90 servo system with absolute encoder for pendulum motion and incremental encoder for rotary table rotation; precise position and speed control and easy system wiring.



- Controller

Siemens SIMATIC S7-1200 controller, integrated PID control function, to ensure the accurate control of water flow, efficient operation ability to ensure that the system can be controlled in real time.



Practical and safe design


- Quick-change pendulum fixing structure, convenient for pendulum replacement

- Pendulum swing electrical limit + mechanical limit double protection

- Pendulum tube home position (0 ° relative to the vertical line) sensor detection, to ensure the stability of the repeated movement, and can automatically return to the original position.

- Water-proof rotating platform, up to 200Kg load-bearing capacity, multiple linear tracks for easy installation of test samples.

- Motorized lifting of the rotating platform for easy installation of test specimens


- Integrated water supply system: water tanks, pumps, control valves, flow sensors and other combinations to form an independent system, the external connection using quick couplings, easy to install, move and maintenance.

- The water tank is equipped with a low level switch and a high level switch, which keeps the water tank level at a high level through automatic water replenishment control.

- The water system is equipped with sufficient filters to avoid debris entering the water tank, pump and nozzle, and the filters need to be replaced regularly.



Simple and easy-to-use operation


① The main signals of the equipment and alarm trigger display, such as power supply phase sequence, motor failure, tank level, etc.

② pipeline set flow, real-time flow and pipeline pressure curve display

③ Digital display of pipeline set flow rate, real-time flow rate, pipeline pressure, pendulum angle, pendulum running speed and turret running speed.

④ Current test level and test method display

⑤ Test progress display

⑥ Information prompts for equipment operation

⑦ Protective operation and stop touch keys, each operation needs to be confirmed.

⑧ All actions can be controlled manually

① IPX3/X4/X4K pendulum test method parameter settings: single-hole flow, swing angle, swing speed, rotary table speed, the number of holes in each size of the pendulum, test time

② IPX3/X4 shower test method parameter settings: flow, rotary table speed, test time

③ IPX5/X6/X6K parameter setting: flow rate, rotary table speed, test time.

Each parameter modification needs to be saved before it takes effect.




Design and technical parameters

Equipment Size

Acutech Automation Testing Technology Co.,Ltd.|Cyclic Corrosion Chamber|Salt Spray Chamber|Composite Salt Spray Chamber|Walk-in Salt Spray Chamber|Sand Dust Chamber|Rainfall Chamber|Protection Level Test Chamber|IPX4K|IPX9K|IP5X|IP6X