2024/3/13
Applicable standards
ISO 20653,IPX9K
IEC 60529,IPX9
GB/T 30038,IPX9K
GB/T 4208,IPX9
IEC 60068-2-18,IPX9
VW 80101,5.5.2,IPX9K
SMTC 3 800 001,6.13,IPX9K
DIN 40050-9,IPX9K
DIN VDE470,Part1,IPX9
Impact Test Report
Test Requirements:rate between (15±1)l/min to reach a distribution impact force of 0,9-1,2N
Test Results:
-40mm
-30mm
-20mm
-10mm
0mm
10mm
20mm
30mm
40mm
1.07N
1.12N
1.02N
1.05N
1.03N
1.00N
1.03N
1.07N
1.05N
High-performance components
⚫ High Pressure Piston Pumps
|
|
⚫ Pressure sensors |
|
⚫ Flow Sensor
|
|
⚫ Solenoid Valves |
|
⚫ Nozzles |
|
⚫ Nozzle adjustment |
|
⚫ Sample Installation
|
|
⚫ Pressure Regulation
|
|
⚫ Separation of water and electricity
|
|
|
- The main signals and alarm triggers of the equipment are displayed, such as power supply phase sequence, motor failure, tank door signal, etc.
|
|
- The spraying time of each nozzle can be set individually, and nozzles with a spraying time of 0 do not operate. - The interval time between two neighboring nozzles can be set, and an interval time of 0 means continuous spraying. - The interval time between each test cycle can be set, and an interval of 0 means continuous operation. - Rotary table speed setting up to 20r/min - The maximum value of water tank temperature setting is 85℃. - Each parameter modification needs to be saved before taking effect.
|
Detailed technical specifications